home *** CD-ROM | disk | FTP | other *** search
-
- HP ScanJet scanners and Microsoft « Windows 95 drivers - how to install
-
- The following instructions are for pre-installed, non-Windows 95 scanning
- software, HP DeskScan II, version 2.2.
-
- HP C2502 CARD (ISA WITHOUT SWITCHES)
- 1. Copy HPSJCLAS.DLL to the Win 95 System directory and SCANJET.INF to the
- Win 95 INF directory.
- a. Open MS-DOS prompt by clicking on Start menu - Programs and selecting
- MS-DOS Prompt.
- b. Insert the driver diskette in the floppy drive.
- c. At the MS-DOS prompt copy HPSJCLAS.DLL file from the diskette to the
- Win95 system directory. The following assumes that your diskette
- drive is a: and Win 95 was installed on C:\Windows:
- copy a:\hpsjclas.dll c:\windows\system
- d. At the MS-DOS prompt copy SCANJET.INF file from the diskette to the
- Win95 INF directory. The following assumes that your diskette drive
- is a: and Win 95 was installed on C:\Windows:
- copy a:\scanjet.inf c:\windows\inf
- e. At the MS-DOS prompt type exit to return to windows.
-
- 2. Use "Add New Hardware" in the Control Panel to add a SCSI controller.
- a. Select "No" when Windows 95 asks if you want it to search for new
- hardware.
- b. Select "SCSI controllers" as the hardware type. Push "Next".
- c. Push the "Have Disk..." button when asked to identify the manufacturer
- and model for your new hardware. Click "OK" to copy manufacturer files
- from a:\.
- d. Select "Symbios Logic 53C400A (HP Version) SCSI Adapter" as the model
- for your new hardware. Click "Next".
- e. Windows 95 will display which resources it plans to use for your new
- hardware. Click "Next" then "Finish".
-
- 3. Turn off the computer. If the card is not already physically in the
- computer, insert it now. Connect the scanner to the card's connector.
- Make sure the scanner is terminated. Make sure the scanner is turned ON
- prior to step 4.
-
- 4. Turn on the computer. You will be asked for the disk with the drivers
- on it. Specify the diskette drive location (usually a:\) .
-
- NOTE:
-
- If you are not asked for the scanner drivers at bootup (after you log in),
- and your scanner was turned on before and during boot, go to the System
- control panel (Press Start, Settings, Control Panel, then double
- click on System. Click on the device manager tab.). If there is a yellow
- exclamation mark next to the "Symbios Logic 53C400A (HP Version) SCSI
- Adapter" you need to adjust the resources for your card (See Windows 95
- documentation for more information). Click on "Symbios Logic 53C400A
- (HP Version) SCSI Adapter", and the Properties button, select the
- "Resources" tab to examine possible device conflicts. If the "conflict
- device list" area shows "No conflicts" try checking the "Use automatic
- settings" checkbox. If there is a conflict, adjust the resources (See
- Windows 95 documentation). When you are done press "OK". If values
- selected are correct, your scanner should be detected and you will be
- prompted for the driver diskette.
-
- 5. Your system will reboot automatically.
-
- 6. Your drivers are now installed. Use "Scanner Test" to test the installation.
-
- NOTE:
- SCSI address test is not supported with Windows 95.
-
- THIRD-PARTY SCSI CARD
- 1. Copy HPSJCLAS.DLL to the Win 95 System directory and SCANJET.INF to the
- Win 95 INF directory
- a. Open MS-DOS prompt by clicking on Start menu - Programs and selecting
- MS-DOS Prompt.
- b. Insert the driver diskette in the floppy drive.
- c. At the MS-DOS prompt copy HPSJCLAS.DLL file from the diskette to the
- Win95 system directory. The following assumes that your diskette drive
- is a: and Win 95 was installed on C:\Windows:
- copy a:\hpsjclas.dll c:\windows\system
- d. At the MS-DOS prompt copy SCANJET.INF file from the diskette to the
- Win95 INF directory. The following assumes that your diskette drive
- is a: and Win 95 was installed on C:\Windows:
- copy a:\scanjet.inf c:\windows\inf
-
- 2. Use the "Device Manager" tab in "System" in the Control Panel to verify
- that a SCSI controller has already been installed. If not use "Add New
- Hardware" in the Control Panel to add the SCSI controller you own. If
- the SCSI controller you own is not listed as a choice in "Add New
- Hardware," you must contact the SCSI controllers manufacturer to obtain
- a Windows 95 driver.
-
- 3. Turn off the computer. If the card is not already physically in the
- computer, insert it now. Connect the scanner to the card's connector.
- Make sure that if the scanner is the last device on the SCSI chain and
- that it is terminated. Make sure the scanner is turned ON before step 4.
-
- 4. Turn on the computer. You will be asked for the disk with the drivers
- on it.
-
- NOTE:
-
- If you are not asked for the scanner drivers at bootup (after you
- log in), and your scanner was turned on before and during boot, go
- to the System control panel. (Press Start, Settings, Control
- Panel, then double click on System. Click on the device manager
- tab.) Examine your Device configuration, if there is a yellow
- exclamation mark next to your SCSI card you might have to adjust
- your card resources. Please consult Windows 95 documentation,
- your SCSI card documentation or your SCSI card manufacturer.
-
- 5. Your system will reboot automatically
-
- 6. Your drivers are now installed. Use "Scanner Test" to test the
- installation.
-
- NOTE:
-
- SCSI address test is not supported with Windows 95.
-
- HP C2503 CARD (MICROCHANNEL WITHOUT SWITCHES)
- 1. Identify what Input/Output (I/O) region your interface card is using.
- Consult the documentation that came with your computer to find out
- how to do this.
-
- 2. Copy HPSJCLAS.DLL to the Win 95 System directory and SCANJET.INF to the
- Win 95 INF directory.
- a. Open MS-DOS prompt by clicking on Start menu - Programs and
- selecting MS-DOS Prompt.
- b. Insert the driver diskette in the floppy drive.
- c. At the MS-DOS prompt copy HPSJCLAS.DLL file from the diskette to
- the Win95 system directory. The following assumes that your diskette
- drive is a: and Win 95 was installed on C:\Windows:
- copy a:\hpsjclas.dll c:\windows\system
- d. At the MS-DOS prompt copy SCANJET.INF file from the diskette to the
- Win95 INF directory. The following assumes that your diskette drive
- is a: and Win 95 was installed on C:\Windows:
- copy a:\scanjet.inf c:\windows\inf
-
- 3. Use "Add New Hardware" in the Control Panel to add your scanner and
- interface card.
- a. Select "No" when Windows 95 asks if you want it to search for new
- hardware.
- b. Select "Other devices" as the hardware type. Push "Next".
- c. Push the "Have Disk..." button when asked to identify the
- manufacturer and model for your new hardware. Click "OK" to copy
- manufacturer files from a:\.
- d. Select "HP ScanJet on C2503" as the model for your new hardware. Push
- "Next".
- e. Windows 95 will display which resources it plans to use for your new
- hardware. If those do not match the resources your card is set to,
- do not allow your computer to be shut down. Instead, go to the
- "Device Manager" tab in "System" in the control panel and modify the
- resources allocated for the "HP ScanJet on C2503" to match the card's
- settings.
-
- 4. Turn off the computer. If the card is not already physically in the
- computer, insert it now. Connect the scanner to the card's connector.
- Turn on the computer.
-
- 5. Your drivers are now installed. Use "Scanner Test" to test the
- installation.
-
- NOTE:
- The SCSI address test is not supported with Windows 95.
-
- HP C1752/C1753 INTERFACE CARD (ISA OR MICROCHANNEL WITH SWITCHES)
- 1. Identify what memory region the switches on your interface card are
- set to. Consult the documentation that came with your scanner to find
- out how to do this.
-
- 2. Copy HPSJCLAS.DLL to the Win 95 System directory and SCANJET.INF to the
- Win 95 INF directory.
- a. Open MS-DOS prompt by clicking on Start menu - Programs and
- selecting MS-DOS Prompt.
- b. Insert the driver diskette in to the floppy drive.
- c. At the MS-DOS prompt copy HPSJCLAS.DLL file from the diskette to the
- Win95 system directory. The following assumes that your diskette drive
- is a: and Win 95 was installed on C:\Windows:
- copy a:\hpsjclas.dll c:\windows\system
- d. At the MS-DOS prompt copy SCANJET.INF file from the diskette to the
- Win95 INF directory. The following assumes that your diskette drive is
- a: and Win 95 was installed on C:\Windows:
- copy a:\scanjet.inf c:\windows\inf
-
- 3. Use "Add New Hardware" in the Control Panel to add your scanner and
- interface card.
- a. Select "No" when Windows 95 asks if you want it to search for new
- hardware.
- b. Select "Other devices" as the hardware type. Push "Next".
- c. Push the "Have Disk..." button when asked to identify the manufacturer
- and model for your new hardware. Click "OK" to copy manufacturer files
- from a:\.
- d. Select "HP ScanJet IIc/IIp on C1752/C1753" as the model for your new
- hardware. Push "Next".
- e. Windows 95 will display which resources it plans to use for your new
- hardware. If those do not match the resources your card is set to,
- do not allow your computer to be shut down. Instead, go to the "Device
- Manager" tab in "System" in the control panel and modify the resources
- allocated for the "HP ScanJet IIc/IIp on C1752/CI753" to match the card's
- settings.
-
- 4. Turn off the computer. If the card is not already physically in the
- computer, insert it now. Connect the scanner to the card's connector.
- Turn on the computer.
-
- 5. Your drivers are now installed. Use "Scanner Test" to test the
- installation.
-
- NOTE:
- The SCSI address test is not supported with Windows 95.
-
- HP SCANJET PLUS SCANNER AND INTERFACE CARD
- 1. Identify what memory region and interrupt the switches and jumpers on your
- interface card are set to. Consult the documentation that came with your
- scanner to find out how to do this.
-
- 2. Copy HPSJCLAS.DLL to the Win 95 System directory and SCANJET.INF to the
- Win 95 INF directory.
-
- a. Open MS-DOS prompt by clicking on Start menu - Programs and selecting
- MS-DOS Prompt.
- b. Insert the driver diskette in to the floppy drive.
- c. At the MS-DOS prompt copy HPSJCLAS.DLL file from the diskette to the
- Win95 system directory. The following assumes that your diskette drive
- is a: and Win 95 was installed on C:\Windows:
- copy a:\hpsjclas.dll c:\windows\system
- d. At the MS-DOS prompt copy SCANJET.INF file from the diskette to the
- Win95 INF directory. The following assumes that your diskette drive
- is a: and Win 95 was installed on C:\Windows:
- copy a:\scanjet.inf c:\windows\inf
-
- 3. Use "Add New Hardware" in the Control Panel to add your scanner and
- interface card.
- a. Select "No" when Windows 95 asks if you want it to search for new
- hardware.
- b. Select "Other devices" as the hardware type. Push "Next".
- c. Push the "Have Disk...." button when asked to identify the manufacturer
- and model for your new hardware. Click "OK" to copy manufacturer files
- from a:\.
- d. Select "HP ScanJet-Plus" as the model for your new hardware. Push
- "Next".
- e. Windows 95 will display which resources it plans to use for your new
- hardware. If those do not match the resources your card is set to,
- do not allow your computer to be shut down. Instead, go to the "Device
- Manager" tab in "System" in the control panel and modify the resources
- allocated for the "HP ScanJet Plus" to match the card's settings.
-
- 4. Turn off the computer. If the card is not already physically in the
- computer, insert it now. Connect the scanner to the card's connector.
- Turn on the computer.
-
- 5. Your drivers are now installed. Use "Scanner Test" to test the
- installation.
-
- NOTE:
-
- The SCSI address test is not supported with Windows 95.
-
- Windows is a U.S. trademark of Microsoft Corporation.
-
- Microsoft « is a U.S. registered trademark of Microsoft
- Corporation.
-
- Copyright Hewlett-Packard Co. 1995
- This information is subject to change without notice and
- is provided "as is" with no warranty.
- Hewlett-Packard shall not be liable for any direct,
- indirect, special, incidental or consequential damages
- in connection with the use of this material.